ZW1810 series intelligent distribution monitoring terminal is an intelligent monitoring module designed for remote control & management of front-end monitoring box. It has intelligent remote monitoring and management functions used mainly realizes the functions of starting and stopping the load of monitoring box, the working state of reclosure, the state of power surge arrester, and the ambient temperature monitoring. At the same time, to achieve linkage with fan by temperature changes to control the temperature in box. In addition, it has the ability to realize two-way communication with the central management system through network port. Real-time interaction with the monitoring platform of monitoring center through network to report on-site conditions. When network interruption, equipment damage, mains power interruption, equipment power status change, cabinet temperature is too high, and the door is forced to open, alarm information will be sent uniformly; The optional backup battery module of the equipment maintains the normal power supply of monitoring unit and switch/ONU in case of mains power failure/tripping to ensure the normal operation of system for a period of time. It can be used with our company's independent monitoring center platform software to achieve remote centralized monitoring of front-end equipment. It can also be connected to a third-party monitoring platform through a protocol to achieve centralized monitoring Through the monitoring center platform software, managers can realize the centralized management of front-end equipment, remotely view the real-time operation status of front-end equipment, and operate the power supply status of the equipment. When the front-end equipment is abnormal, the monitoring center can notify the management personnel through mobile phone text messages, voice calls, and other forms, and form a work order to notify the maintenance personnel to troubleshoot in time. This remote centralized management method can reduce labor Input, save maintenance costs and improve maintenance efficiency. It can be widely used in smart transportation checkpoints, safe cities, highways, water conservancy and hydropower industries.
1、Three DC12V+one DC12/AC24 compatible output control channels, which can control the start and stop status of the connected load, and can monitor whether the load working status is normal;
2、4 channels AC220V output control, can control the start and stop status of the connected load, (one of which has timing control function) and can monitor whether the load working status is normal;
3、A temperature sensor chip is set on the control module, and the controller can monitor the internal temperature of the monitoring box. The controller can start and stop the cooling fan according to the set temperature range;
4、The controller is equipped with a 10/100M network port, which realizes the remote real-time management of multiple controllers by a set of management systems. The controller and the management system can communicate bidirectionally: the management system can issue operation commands, control parameters and application programs to the controller; the controller can send the load operation status, field environment and alarm parameters to the management system; when the controller cannot communicate with the management system At this time, the controller can automatically restart the front-end load according to a certain strategy to achieve unattended resolution of network failures caused by field network device crashes;
5、The controller reserves one RS485 interface for easy access to other smart devices;
6、The controller reserves 4 channels of digital acquisition interfaces for easy status acquisition;
7、The controller can collect load operating parameters and environmental status parameters in real time, and can regularly report to the management system;
8、 The controller can receive and store the control parameters downloaded by the management system, and it will not be lost when power off;
9、The controller DC controls the channel switch, sampling and terminal devices to meet the requirements of flow capacity and withstand voltage;
10、The program of the intelligent controller can be updated remotely;
11、The controller can be backed up by a lithium battery, which can ensure that the communication is normal for a certain period of time when the system trips or the mains power fails;
12、The relay is closed by default, and the failure of the intelligent controller does not affect the power supply of the front-end equipment;
13、The controller has a built-in main control circuit board for paint spraying and moisture-proof treatment;
14、Stable work: -5~55℃;
15、Working humidity: 0~95%RH.